Water remained inside
No error code was reported with the no-drain condition.
The useful clue was broader than standing water: diagnostic mode failed to start both circulation and drain. That put supply, wiring and control commands ahead of blind board replacement.
A similar symptom can have a different cause on another appliance or model.
No error code was reported with the no-drain condition.
The circulation and drain functions were both inactive under direct tests.
Voltage at the load separates an absent command from a pump or obstruction that cannot respond.
The evidence supports testing the shared command and wiring path before treating the drain pump as the only fault. It does not confirm the control board.
Qualified service should verify model-specific supply and commanded voltage, inspect the pump for debris and check the air gap. Record which direct tests fail before selecting a board or pump.