The fill tube froze again
Clearing the ice alone would not explain why new water continued to freeze in the same path.
Before treating the frozen tube as a board-and-sensor overcooling problem, the discussion added a mechanical alternative: water leaking past a closed solenoid and freezing a drop at a time.
A similar symptom can have a different cause on another appliance or model.
Clearing the ice alone would not explain why new water continued to freeze in the same path.
That branch remained possible if the fill-line heat or temperature control was wrong.
Slow leakage provides water that can freeze between normal fill commands.
The source does not close the cause, but it establishes the needed split: determine whether water enters with the valve de-energized before replacing sensors and a control for overcooling.
After safely thawing the line, observe whether water reappears when no fill is commanded and record line temperature. A technician can then separate valve seepage from control and defrost branches.