E15, Water in the Tub, but No Familiar Flood Tray
On this SHE3AR72UC/25, the usual advice to inspect a lower pan switch did not match the machine. The useful next question was which float input told the board that the water level was unsafe.
What happened
- The dishwasher arrived with E15 and water still inside.
- After a cycle was started, the machine drained and the drain pump operated.
- The circulation and drain pumps were reported to work.
- The code stopped appearing during the discussion.
- The technician found no conventional lower tray and flood switch used on other Bosch platforms.
A similar symptom with E15 can have a different cause or level-sensing design on another model. This case matters because the exact SHE3AR72UC/25 construction changed the test path.
The model-specific distinction
The discussion identified a float switch mounted in an upper enclosure rather than a flood switch in a lower catch pan. Those devices should not be treated as interchangeable names. The control still needs an input before deciding that the water condition is unsafe.
Two unconfirmed explanations remained: the inlet valve may have stayed open long enough to overfill the tub, or the float input may have stuck or reported the wrong state. A control fault was also considered, but no test result established it.
Evidence to collect if E15 returns
- Photograph the code before clearing or draining the machine.
- Record the water level and whether filling continues longer than expected.
- Note whether E15 appears during fill, wash or while the dishwasher is idle.
- Check from outside for visible supply, door and drain leakage.
- Give the technician the full model suffix so the correct float circuit is tested.
The thread did not confirm a lasting repair. Its value is the platform exception and the observation that an intermittent code does not erase the earlier overfill or float signal.
Does every Bosch E15 machine have a flood switch in a lower pan?
No. The SHE3AR72UC/25 case described here used a different float-input arrangement, which is why the exact model matters.
Did the thread prove that the inlet valve was stuck?
No. Overfill from the valve and a stuck float input remained diagnostic branches; neither was reported as confirmed.