The door remained open
The complaint was not simply a misaligned handle; the assist mechanism did not pull and hold the door shut.
The door-assist system needed to hold vacuum. Once ordinary shelf interference was excluded, replacing the faulty closer module restored repeatable closing.
A similar symptom can have a different cause on another appliance or model.
The complaint was not simply a misaligned handle; the assist mechanism did not pull and hold the door shut.
A hose that can be blown through does not demonstrate that the assembled closer is leak-free.
About twenty open-close attempts after module replacement provided the reported outcome.
The completed repair supports a failure within the vacuum-assist closer module. An expert considered a vacuum leak the likely mechanism, but the removed module was not tested to locate the leak.
After the module was replaced and the refrigerator restarted, the door operated normally through roughly twenty repeated tests.
First remove food or shelf interference and document the exact door gap. If the assist still fails, a technician can test whether the vacuum assembly holds and identify the correct model-specific module.