Failed-compressor case · LG

A Standard Compressor Job Did Not Resolve the Original Complaint

With no cooling after the compressor, filter and purge, the diagnosis had to return to first principles: was the original fault a leak, or did the repair introduce a restriction or valve problem?

Case snapshot

What the source establishes

  • A 2018 LG did not cool or freeze.
  • The compressor and filter were replaced and the system was purged, but the complaint remained.
  • The technician said this was the second recent case with the same unresolved result.
  • The discussion reopened the original diagnosis and listed leak, oil, restricted brazed tubing, overheated three-way valve, purge direction and a leaking joint as distinct branches.
  • No pressure readings or final repair were posted.

A similar symptom can have a different cause on another appliance or model.

Diagnostic process

How the evidence narrowed the diagnosis

Attempt

Compressor and filter were replaced

The refrigerator remained unable to cool, so the completed work did not prove the original diagnosis.

Missing evidence

No operating pressures were supplied

The experts asked for gauge readings because the same symptom can emerge from different sealed-system paths.

Reopened branches

Leak and post-repair restriction both remained

Oil, a pinched joint, three-way valve heat damage, purge direction and a leaking braze were kept separate.

What the evidence supports

What the evidence supports

The evidence supports only that the compressor replacement did not close the diagnosis. A measured sealed-system evaluation is required to distinguish an incorrect original diagnosis from a restriction or leak created or missed during service.

What to do next

What should be verified next

Document low- and high-side behavior, temperatures, charge method and every joint disturbed. A sealed-system technician should then test the branch indicated by those measurements instead of repeating the compressor replacement.

Refrigerant and pressure safety: gauge interpretation, leak testing, nitrogen use, brazing and refrigerant charging require qualified sealed-system service.