Compressor and filter were replaced
The refrigerator remained unable to cool, so the completed work did not prove the original diagnosis.
With no cooling after the compressor, filter and purge, the diagnosis had to return to first principles: was the original fault a leak, or did the repair introduce a restriction or valve problem?
A similar symptom can have a different cause on another appliance or model.
The refrigerator remained unable to cool, so the completed work did not prove the original diagnosis.
The experts asked for gauge readings because the same symptom can emerge from different sealed-system paths.
Oil, a pinched joint, three-way valve heat damage, purge direction and a leaking braze were kept separate.
The evidence supports only that the compressor replacement did not close the diagnosis. A measured sealed-system evaluation is required to distinguish an incorrect original diagnosis from a restriction or leak created or missed during service.
Document low- and high-side behavior, temperatures, charge method and every joint disturbed. A sealed-system technician should then test the branch indicated by those measurements instead of repeating the compressor replacement.