The Broil Element Glowed During Bake as E2 F3 Appeared
The oven also reportedly entered self-clean without being asked. That is an unsafe control pattern, not a situation for repeated trial cycles.
What made this more than a sensor guess
- E2 F3 accompanied an overtemperature complaint.
- The oven reportedly entered self-clean on its own.
- The broil element operated during bake.
- The bake element did not operate.
- The sensor was measured while the oven was near 300°F.
The same symptom can have a different cause on another oven. The abnormal element command must be separated from whether the sensor reports temperature correctly.
Why the sensor reading was incomplete
A resistance value has meaning only when compared with the specified temperature table. The discussion did not preserve the number or a cold reference reading. The glowing broil element during bake therefore kept a stuck relay or control-output fault under suspicion.
What qualified service should establish
- Stop further heating cycles and record the complete model.
- Compare the sensor at known temperatures with its model chart.
- Verify which output is commanded and which relay remains closed.
- Inspect the bake circuit separately from the uncontrolled broil circuit.
Overheat and fire safety: stop using the oven and switch off its circuit if an element stays on in the wrong mode or self-clean starts unexpectedly. Do not test it energized as a homeowner.
A replacement that did not solve the fault
A repair that did not follow the obvious path
Recently published cases
Whirlpool F03 E01 with Drain Running Forever
A Whirlpool ran its drain forever, flashed the lock lamp and showed F03/E01 after a level-sensor connection changed. The signal path came first.
Maytag MVW7230HW0 Quick Wash Stuck at 17 Minutes
A Maytag MVW7230HW0 kept operating while Quick Wash remained at 17 minutes. The case separates a stalled countdown from a simple no-spin fault.
Maytag F1E2 After Drain Worked and Programs Stopped
A Maytag drained correctly, then programs stopped after pause and F1E2 appeared. The case separates standing-water door lock from motor control.