Two Left XLO Burners Stopped at the Same Time
This PRG366WH/03 uses individual burner controllers, but a simultaneous pair failure made the shared board path more important than ordering both controllers first.
What the model discussion established
- The exact model was Thermador PRG366WH/03.
- Both left XLO burners were inoperative.
- Individual burner-control modules were described as mounted at the valves.
- The DSI-style control concept manages ignition and reignition.
A similar symptom can have a different cause on another range. Two failed burners can still share a command, supply or software path even when each has its own controller.
Why the shared board path came first
The proposed sequence was to verify supply from the main board and the state of relay K116 during a burner request. If the shared feed was absent, replacing both valve-mounted controllers would not address the upstream interruption.
The display board, which carries control software, remained a later branch if the main board path and individual controllers were proven.
What the thread did not prove
No service measurement or final part replacement was reported. The page therefore records the system layout and diagnostic order, not a confirmed K116 or board failure.