Field evidence
HC Returned About Two Weeks After the Sensor Was Replaced
The dryer had been cleaned and the outdoor exhaust was reported strong. That repeat failure made the original sensor-only diagnosis incomplete.
What the repeat failure established
- The complaint was a recurring HC display.
- A temperature sensor had already been replaced.
- The dryer then operated for roughly half a month before the problem returned.
- The machine was described as clean with strong exhaust outdoors.
The same symptom can have a different cause on another dryer. A returning code after a new sensor is evidence to test the whole heat-control chain, not proof that the new sensor failed.
Why the first sensor test was questioned
The author described the original sensor as failed because it did not show continuity. Another technician challenged that conclusion. A thermistor must be compared with the resistance and temperature relationship specified for the exact model; a generic continuity expectation is not enough.
Branches that remained open
- Verify airflow under actual operating conditions, not only an empty visual check.
- Inspect whether the heater or its conductor can contact the cabinet.
- Compare sensor readings with the model temperature chart.
- Test wiring and the control output before replacing another sensor or board.
Fire and electrical safety: stop using a dryer that overheats, smells hot or shows repeated HC. Heater grounding and live control tests require qualified service.
A repair that did not follow the obvious path
Recently published cases
GE Monogram ZDT985SIN6II Had Both Pumps Inactive in Test Mode
A GE Monogram ZDT985SIN6II would not drain, and neither pump ran in diagnostics. The case puts voltage, wiring, debris and air-gap checks before the …
Cove DW24 Error 800140: Start with the Drain Path
A real Cove DW24 case explains what error 800140 supports, what it does not prove, and how to separate the drain pump, hose and …
Samsung Gas Oven Igniter Glowed but Could Not Hold the Valve
A Samsung gas oven igniter glowed and the burner lit, but operation was unstable. Replacing the marginal igniter resolved the case.