The Old Compressor Could Start, but the Replacement Could Not

That comparison shifted the question from “is the board bad?” to “is this compressor electrically compatible with the refrigerator's R600 inverter system?”

Why a new compressor is not proof of compatibility

A compressor may be described as universal within a product family while still being wrong for the refrigerant application, inverter and winding arrangement in front of the technician. In this discussion, the replacement was identified as an R134a application while the refrigerator used R600.

A similar symptom can have a different cause on another refrigerator. A locked rotor, incorrect programming, damaged inverter, harness fault or incompatible compressor can all produce a no-start complaint.

What the wiring comparison revealed

The installed system used three conductors at the compressor. Contributors contrasted that arrangement with the supplied compressor and explained that the inverter expected a different motor architecture. The old compressor starting on the same refrigerator made a blanket “board cannot start anything” explanation less coherent.

The correct verification happens before installation

Match the complete application

Refrigerant application

R600 and R134a labeling cannot be treated as interchangeable.

Drive architecture

The inverter and compressor motor must be designed to work together.

Part documentation

The refrigerator model, compressor part number, service bulletin and programming requirements must agree.

No completed replacement was reported

The source converged on the compatibility mismatch but did not report installation of the correct compressor or a successful final run. This page preserves the failed-replacement evidence without claiming a completed repair.

Flammable refrigerant and electrical safety: R600 systems require qualified equipment, ventilation and ignition-control procedures. Do not open the sealed system, improvise compressor wiring or energize an unmatched compressor.